alarm_handler(3)



alarm_handler(3erl)        Erlang Module Definition        alarm_handler(3erl)

NAME
       alarm_handler - An Alarm Handling Process

DESCRIPTION
       The alarm handler process is a gen_event event manager process that re-
       ceives alarms in the system. This process is not intended to be a  com-
       plete  alarm  handler.  It defines a place to which alarms can be sent.
       One simple event handler is installed in the alarm handler at  startup,
       but users are encouraged to write and install their own handlers.

       The  simple event handler sends all alarms as info reports to the error
       logger, and saves all in a list. This list can be passed to a  user-de-
       fined  event  handler,  which can be installed later. The list can grow
       large if many alarms are generated. This is a good reason to install  a
       better user-defined handler.

       Functions are provided to set and clear alarms. The alarm format is de-
       fined by the user. For example, an event handler for SNMP  can  be  de-
       fined, together with an alarm Management Information Base (MIB).

       The alarm handler is part of the SASL application.

       When  writing  new  event handlers for the alarm handler, the following
       events must be handled:

         {set_alarm, {AlarmId, AlarmDescr}}:
           This event is generated by alarm_handler:set_alarm({AlarmId,  Alar-
           mDecsr}).

         {clear_alarm, AlarmId}:
           This event is generated by alarm_handler:clear_alarm(AlarmId).

       The  default  simple  handler is called alarm_handler and it can be ex-
       changed  by  calling  gen_event:swap_handler/3  as  gen_event:swap_han-
       dler(alarm_handler, {alarm_handler, swap}, {NewHandler, Args}). NewHan-
       dler:init({Args, {alarm_handler, Alarms}}) is called. For more details,
       see gen_event(3erl) in STDLIB.

EXPORTS
       clear_alarm(AlarmId) -> void()

              Types:

                 AlarmId = term()

              Sends event clear_alarm to all event handlers.

              When receiving this event, the default simple handler clears the
              latest received alarm with id AlarmId.

       get_alarms() -> [alarm()]

              Returns a list of all active alarms. This function can  only  be
              used when the simple handler is installed.

       set_alarm(alarm())

              Types:

                 alarm() = {AlarmId, AlarmDescription}
                 AlarmId = term()
                 AlarmDescription = term()

              Sends event set_alarm to all event handlers.

              When receiving this event, the default simple handler stores the
              alarm. AlarmId identifies the alarm and is used when  the  alarm
              is cleared.

SEE ALSO
       error_logger(3erl), gen_event(3erl)

Ericsson AB                        sasl 4.0                alarm_handler(3erl)

Man(1) output converted with man2html