sane-coolscan3(5)



sane-coolscan3(5)        SANE Scanner Access Now Easy        sane-coolscan3(5)

NAME
       sane-coolscan3 - SANE backend for Nikon Coolscan film scanners

DESCRIPTION
       The  sane-coolscan3 library implements a SANE (Scanner Access Now Easy)
       backend that provides access to Nikon  Coolscan  film  scanners.   Some
       functions  of  this backend should be considered beta-quality software.
       Most functions have been stable for a long time, but of course new  de-
       velopment  can  not  and will not function properly from the very first
       day.

       At present, the following scanners are known to work with this backend:

              Model:                       Connection Type
              ---------------------------  -------------------
              LS-30 (Coolscan III)         SCSI
              LS-40 ED (Coolscan IV)       USB
              LS-50 ED (Coolscan V)        USB
              LS-2000                      SCSI
              LS-4000 ED                   IEEE 1394
              LS-8000 ED                   IEEE 1394

       Please send mail to sane-devel@lists.alioth.debian.org to  report  suc-
       cesses or failures.

OPTIONS
       The options the backend supports can either be selected through command
       line options to programs like scanimage or through GUI elements in  xs-
       canimage or xsane.

       Valid command line options and their syntax can be listed by using
              scanimage --help -d coolscan3:<interface>:<device>
       where  <interface>  and  <device> specify the device in question, as in
       the configuration file (see next section). The -d parameter and its ar-
       gument  can be omitted to obtain information on the first scanner iden-
       tified. Use the command
              scanimage -L
       to list all devices recognized by your SANE installation.

       The options should be fully described by the  description  or  tooltips
       given  by frontend. Here is a description of some of the most important
       options, in the syntax with which they must be supplied to scanimage:

       --frame <n>
              This option specifies which frame to operate on, if a  motorized
              film  strip feeder or APS adapter are used. The frame number <n>
              ranges from 1 to the number of frames available, which is sensed
              each  time  the  backend  is  initialized (usually each time you
              start the frontend).

       --subframe <x>
              This option shifts the scan window by the specified amount  (de-
              fault unit is mm).

       --infrared=yes/no
              If  set  to  "yes",  the scanner will read the infrared channel,
              thus allowing defect removal in software. The infrared image  is
              read  during a second scan, with no options altered. The backend
              must not be restarted between the scans.  If you use  scanimage,
              perform  a batch scan with batch-count=2 to obtain the IR infor-
              mation.

       --depth <n>
              Here <n> can either be 8 or the maximum number of bits supported
              by  the scanner (10, 12, or 14). It specifies whether or not the
              scanner reduces the scanned data to 8 bits before sending it  to
              the backend. If 8 bits are used, some information and thus image
              quality is lost, but the amount of data is smaller  compared  to
              higher  depths.  Also,  many  imaging programs and image formats
              cannot handle depths greater than 8 bits.

       --autofocus
              Perform autofocus operation. Unless otherwise specified  by  the
              other options ( --focus-on-centre and friends), focusing is per-
              formed on the centre of the selected scan area.

       --ae-wb

       --ae   Perform a pre-scan to calculate exposure  values  automatically.
              --ae-wb  will maintain the white balance, while --ae will adjust
              each channel separately.

       --exposure
              Multiply all exposure times with this value. This  allows  expo-
              sure correction without modifying white balance.

       --load Load the next slide when using the slide loader.

       --eject
              Eject  the  film  strip  or  mounted  slide when using the slide
              loader.

       --reset
              Reset scanner. The scanner will perform the same action as  when
              power  is  turned on: it will eject the film strip and calibrate
              itself. Use this whenever the scanner refuses  to  load  a  film
              strip properly, as a result of which --eject does not work.

CONFIGURATION FILE
       The  configuration  file  @CONFIGDIR@/coolscan3.conf  specifies the de-
       vice(s) that the backend will use. Owing to the nature of the supported
       connection  types  SCSI,  USB, and IEEE 1394, the default configuration
       file supplied with the SANE  distribution  should  work  without  being
       edited.

       Each  line  in the configuration file is either of the following, where
       all entries are case-sensitive:

       blank or starting with a '#' character
              These lines are ignored, thus '#' can be used  to  include  com-
              ments.

       containing only the word "auto"
              This  instructs  the  backend to probe for a scanner by scanning
              the buses for devices with know identifiers. This is the  action
              taken when no configuration file is present.

       a line of the form <interface>:<device>
              Here  <interface> can be one of "scsi" or "usb", and <device> is
              the device file of the scanner. Note that IEEE 1394 devices  are
              handled  by the SBP-2 module in the kernel and appear to SANE as
              SCSI devices.

FILES
       @LIBDIR@/libsane-coolscan3.a
              The static library implementing this backend.

       @LIBDIR@/libsane-coolscan3.so
              The shared library implementing this backend (present on systems
              that support dynamic loading).

       @CONFIGDIR@/coolscan3.conf
              Configuration  file for this backend, read each time the backend
              is initialized.

ENVIRONMENT
       SANE_DEBUG_COOLSCAN3
              If the library was compiled with debug support enabled, this en-
              vironment  variable  controls  the debug level for this backend.
              E.g., a value of 128 requests all debug output  to  be  printed.
              Smaller levels reduce verbosity.

SEE ALSO
       sane-scsi(5), sane-usb(5), scanimage(1), xscanimage(1), xsane(1)

BUGS
       Currently,  the SANE protocol does not allow automatically updating op-
       tions whenever the hardware changes. Thus the number of choices for the
       --frame  option  will be fixed when the backend is initialized (usually
       when the user runs the frontend). In particular, if there  is  no  film
       strip  in  the automatic film strip feeder when the backend is initial-
       ized, the frame option will not appear at  all.  Also,  restarting  the
       frontend after swapping film adapters is strongly recommended.

       Linux  kernels  prior to 2.4.19 had a patch that truncated INQUIRY data
       from IEEE 1394 scanners to 36 bytes, discarding vital information about
       the  scanner.  The  IEEE 1394 models therefore only work with 2.4.19 or
       later.

       No real bugs currently known, please report any to the SANE developers'
       list.

AUTHORS
       coolscan3  written by A. Zummo (a.zummo@towertech.it), based heavily on
       coolscan2 written by Andras Major (andras@users.sourceforge.net).

@PACKAGEVERSION@                  11 Jul 2008                sane-coolscan3(5)

Man(1) output converted with man2html
list of all man pages