sane-teco3(5) SANE Scanner Access Now Easy sane-teco3(5)
NAME
sane-teco3 - SANE backend for TECO / RELISYS scanners
DESCRIPTION
The sane-teco3 library implements a SANE (Scanner Access Now Easy)
backend that provides access to some TECO SCSI flatbed scanners. This
backend should be considered alpha-quality software! TECO scanners are
sold under various brands like RELYSIS, PIOTECH, TRUST. This backend
may or may not support yours.
The scanners that should work with this backend are:
Vendor Model TECO model status
--------------------------- ---------- ----------
Relisys Scorpio VM3552 tested
Plustek OpticPro 2400SP VM3552 untested
PIOTECH Splendeur 3024 VM3552 tested
Trust Imagery 2400 SP VM3552 tested
Trust Imagery 4800 SP+ VM3552 tested
Trust Imagery 9600 SP VM3552 untested
The TECO VM number can usually be found at the back of the scanner. It
is also part of the FCC ID.
The options the backend supports can either be selected through command
line options to programs like scanimage or through GUI elements in xs-
canimage or xsane.
If you have any success with a scanner not listed here, or if you have
any strange behavior, please report to the backend maintainer or to the
SANE mailing list.
Valid command line options and their syntax can be listed by using
scanimage --help -d teco3
Scan Mode
--mode selects the basic mode of operation of the scanner valid choices
are Black & White , Grayscale and Color The Black & White mode
is black and white only (1 bit). Grayscale will produce 256 lev-
els of gray (8 bits). Color will produce a 24 bits color image.
--resolution
selects the resolution for a scan. The scanner can do all reso-
lutions between 1 and 1200, in increments of 1.
Geometry options
-l -t -x -y
control the scan area: -l sets the top left x coordinate, -t the
top left y coordinate, -x selects the width and -y the height of
the scan area. All parameters are specified in millimeters by
default.
Enhancement options
--custom-gamma
(color mode only) allows the user to specify a gamma table (see
the next 3 parameters).
--red-gamma-table
(color mode only) can be used to download a user defined gamma
table for the red channel. The table must be 1024 bytes long.
--green-gamma-table
(color mode only) can be used to download a user defined gamma
table for the green channel. The table must be 1024 bytes long.
--blue-gamma-table
(color mode only) can be used to download a user defined gamma
table for the blue channel. The table must be 1024 bytes long.
--preview
requests a preview scan. The resolution used for that scan is 22
dpi and the scan area is the maximum allowed. The scan mode is
user selected. The default is "no".
CONFIGURATION FILE
The configuration file @CONFIGDIR@/teco3.conf supports only one infor-
mation: the device name to use (eg /dev/scanner).
FILES
@LIBDIR@/libsane-teco3.a
The static library implementing this backend.
@LIBDIR@/libsane-teco3.so
The shared library implementing this backend (present on systems
that support dynamic loading).
ENVIRONMENT
SANE_DEBUG_TECO3
If the library was compiled with debug support enabled, this en-
vironment variable controls the debug level for this backend.
E.g., a value of 128 requests all debug output to be printed.
Smaller levels reduce verbosity.
LIMITATIONS
The windows TWAIN driver has many more options than this SANE backend.
However they are only software adjustments. This backend only imple-
ments what the scanner can support.
BUGS
Not much.
SEE ALSO
sane-scsi(5), scanimage(1), xscanimage(1), xsane(1), sane(7)
AUTHOR
The package is actively maintained by Frank Zago.
http://www.zago.net/sane/#teco3
@PACKAGEVERSION@ 14 Jul 2008 sane-teco3(5)